TRANSMITTER SERIES ROTO-PHASE

Rotary-Roto-Phase-Converter-Transmitter.jpg

Standard Features:

  • Balanced voltage tolerance within 5% under all loading conditions
  • Designed for 24 hour continuous operation
  • Built in surge protection to prevent damage from lightning strikes or power surges in utility lines
  • All units are TEFC designed for outdoor installation
  • 1-YEAR WARRANTY

The TM Series Roto-Phase converter is engineered to operate three-phase radio and television transmitter equipment from a single-phase power supply. The major problem with establishing a transmitter site isn’t in finding a good location that is affordable, but it is finding a site with the proper power supply to operate the equipment load. Most locations would have single-phase power available at the location site, but not the commercial three-phase power needed to operate the transmitter equipment. The advantage to using three-phase transmitter equipment is due to the fact that it operates better than the single-phase equipment. The rectified output of a three-phase transmitter has less of a ripple than the single-phase transmitter and requires less filtering to produce a clean output.

If the availability of the three-phase power does not exist or it is not economically feasible, then the TM Series Roto-Phase converter could be the solution to your problem. The TM Series Roto-Phase converter opens the door for locations to operate transmitter equipment from 5 KW and larger which require a three-phase power input. Models are available in 208, 230, and 460 VAC.

 

 

BUILD-IN CONTROL PACKAGE OPTIONS

  • Magnetic Starter with Overload Protection & PB ON/OFF Station or a Time-Delay Relay
converter diagram
SPECIFICATIONSApprox   
Ship Wt.
MODELSABCDEPANELAUX BANK
TM517.00?14.00"13.00"10.00"12.00"16x12x6 171 Lbs.
TM719.00"16.00"16.00"12.00"12.00"16x12x6 275 Lbs.
TM1023.00"18.00"21.00"13.00"13.00"18x18x10 482 Lbs.
TM1525.00"20.00"24.00"14.00"15.00"18x18x10 687 Lbs.
TM2027.00"22.00"25.00"15.00"17.00"24x24x10 975 Lbs.
TM25(**)25.00"20.00"24.00"14.00"15.00"18x18x10 1286 Lbs.
TM30(**)25.00"20.00"24.00"14.00"15.00"18x18x10 1375 Lbs.
TM40(**)27.00"22.00"25.00"15.00"17.00"24x24x10 1975 Lbs.
TM45(***)25.00"20.00"24.00"14.00"15.00"24x24x10 2061 Lbs.

(**)Two Units Paralleled (***)Three Units Paralleled

NOTE: When ordering the phase converter with the magnetic starter control package, you will need to add the Prefix Letter “C” (Automatic unit with starter, OL protection, and time-delay relay), or Prefix Letter “C/” (Manual unit with starter, OL protection, and push button START/STOP station).

With the addition of optional features, the panel size of the phase converter model may change – Please Consult Factory.

ARCO Electric Products reserves the right to make product changes without prior notification.