SIZES AVAILABLE
|
|
kVAR
|
Catalog #
|
Catalog #
|
Catalog #
|
|
0.5
|
3240.5AMC
|
3480.5AMC
|
3600.5AMC
|
|
1
|
32401AMC
|
34801AMC
|
36001AMC
|
|
1.5
|
32401.5AMC
|
34801.5AMC
|
36001.5AMC
|
|
2
|
32402AMC
|
34802AMC
|
36002AMC
|
|
2.5
|
32402.5AMC
|
34802.5AMC
|
36002.5AMC
|
|
3
|
32403AMC
|
34803AMC
|
36003AMC
|
|
4
|
32404AMC
|
34804AMC
|
36004AMC
|
|
4.5
|
32405AMC
|
34804.5AMC
|
36004.5AMC
|
|
5
|
32406AMC
|
34805AMC
|
36005AMC
|
|
6
|
32407.5AMC
|
34806AMC
|
36006AMC
|
|
7.5
|
32408AMC
|
34807.5AMC
|
36007.5AMC
|
|
10
|
32409AMC
|
348010AMC
|
360010AMC
|
|
12.5
|
324010AMC
|
348012.5AMC
|
360012.5AMC
|
|
15
|
324012.5AMC
|
348015AMC
|
360015AMC
|
|
17.5
|
324015AMC
|
348017.5AMC
|
360017.5AMC
|
|
20
|
324017.5AMC
|
348020AMC
|
360020AMC
|
|
22.5
|
324020AMC
|
348022.5AMC
|
360022.5AMC
|
|
25
|
324022.5AMC
|
348025AMC
|
360025AMC
|
|
27.5
|
324025AMC
|
348027.5AMC
|
360027.5AMC
|
|
30
|
324020AMC
|
348030AMC
|
360030AMC
|
|
32.5
|
324032.5AMC
|
348032.5AMC
|
360032.5AMC
|
|
35
|
324035AMC
|
348035AMC
|
360035AMC
|
|
37.5
|
324037.5AMC
|
348037.5AMC
|
360037.5AMC
|
|
40
|
324040AMC
|
348040AMC
|
360040AMC
|
|
45
|
324045AMC
|
348045AMC
|
360045AMC
|
|
50
|
324050AMC
|
348050AMC
|
360050AMC
|
|
60
|
324060AMC
|
348060AMC
|
360060AMC
|
|
75
|
324075AMC
|
348075AMC
|
360075AMC
|
|
80
|
324080AMC
|
348080AMC
|
360080AMC
|
|
90
|
324090AMC
|
348090AMC
|
360090AMC
|
|
100
|
3240100AMC
|
3480100AMC
|
3600100AMC
|
All units are UL and cUL recognized
5-YEAR WARRANTY on the Capacitor Cells
Construction
The fixed capacitor banks are designed for low voltage linear applications and incorporate high quality single phase cells which are wired in a three phase Delta configuration. The capacitors are housed in a NEMA 3R enclosure panel. The enclosure is manufactured from 16 gauge steel and is furnished with mounting holes for quick and easy installation. Other NEMA rated are available – consult the factory
Capacitor Design
- Internal Pressure Interrupter meets UL 810 requirements. Discharge voltage is less than 50 volts in less than 1 minute after the cell has electrically been removed from circuit.
- Environmentally safe epoxidized soybean-oil dielectric fluid. Soybean-oil is environmentally compatible and biodegradable.
Capacitor Losses
The capacitor design has a total loss which is as low as 2 Watts per kVAR.
Electrical Characteristics
- Capacitance Tolerance is + or – 15%.
- Overcurrent Tolerance is 135% of rated current continuously.
- Overvoltage Tolerance is 110% of rated voltage
- Standard Operating Temperature
- -40 F to +115 F. Operation above 115 F will shorten the capacitor life.
Wiring Cable Insulation
All internal conductors are insulated stranded copper wire rated at 90 C.
Fuse Protection & Indicator Lights (Optional – Add Suffix Letter “L” to Catalog Number)
- The internal protection fuses are time-delay and rated at 600 VAC with the sizing based upon the nominal amperage rating of the kVAR size in accordance with the National Electric Code requirements.
- For single phase applications change Prefix Number from 3 to 1.
- For 208 VAC applications divide kVAR size by .75 to find equivalent in 240 VAC size.